1.
Radiol. bras ; 48(2): 86-92, Mar-Apr/2015. tab
Article in English | LILACS | ID: lil-746624

ABSTRACT

Objective: To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. Materials and Methods: Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. Results: Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). Conclusion: The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. .


Objetivo: Avaliar a evolução da qualidade da imagem de mamógrafos localizados no Estado do Rio de Janeiro, de 2006 a 2011, com base em parâmetros medidos e observados durante inspeções sanitárias. Materiais e Métodos: Estudo descritivo sobre a evolução de parâmetros que condicionam a qualidade da imagem focalizou 52 mamógrafos, inspecionados no mínimo duas vezes, com intervalo de um ano. Resultados: Dos 16 parâmetros avaliados, 7 apresentaram mais de 70% de conformidade: força do dispositivo de compressão (85,1%), processamento dos filmes (72,7%), resposta do filme do serviço (72,7%), detalhes lineares de baixo contraste (92,2%), visualização de massas tumorais (76,5%), ausência de artefatos de imagem (94,1%), existência de processadoras específicas para mamografia (88,2%). Importantes parâmetros apresentaram-se abaixo de 50% de conformidade: realização de testes mensais da qualidade de imagem pelo estabelecimento (28,8%) e detalhes de alto contraste, que dizem respeito à visualização de microcalcificações (47,1%). Conclusão: A análise revelou situações críticas da atuação da vigilância sanitária, cuja prioridade deveria ser dirigida aos estacionários, ou seja, os mamógrafos que permaneceram na situação de não conformidade nas inspeções realizadas com intervalo de um ano. .


Subject(s)
Animals , Rabbits , Calcium Channels, L-Type/metabolism , Muscle Cells/metabolism , Amino Acid Sequence , Calcium Channel Agonists/pharmacology , Calcium-Calmodulin-Dependent Protein Kinases/metabolism , Calmodulin/metabolism , Cell Membrane/drug effects , Cell Membrane/metabolism , Electrophysiology , Heart Ventricles/cytology , Heart Ventricles/metabolism , Ion Channel Gating/physiology , Ligands , Molecular Sequence Data , Patch-Clamp Techniques , Peptides/pharmacology
2.
Radiol. bras ; 40(2): 119-122, mar.-abr. 2007. tab, graf
Article in Portuguese | LILACS | ID: lil-455947

ABSTRACT

OBJETIVO: Foi realizada avaliação da dose de entrada na pele, da dose efetiva e da qualidade da imagem em radiografias de tórax de pacientes adultos. MATERIAIS E MÉTODOS: O estudo realizou-se em oito hospitais, sendo sete públicos (dois filantrópicos) e um particular nos municípios de Angra dos Reis, Cabo Frio, Campos dos Goytacazes, Itaperuna, Niterói, Recife e Rio de Janeiro. Foram avaliadas a dose de entrada na pele e a dose efetiva de 735 radiografias de tórax nas incidências póstero-anterior/ântero-posterior e perfil. No que se refere aos critérios de imagem, foram avaliadas 44 radiografias. RESULTADOS: Constatou-se variação de até nove vezes nos valores da dose de entrada na pele e de até seis vezes na dose efetiva para um mesmo tipo de projeção. Os valores das técnicas radiográficas também apresentaram grandes discrepâncias. A qualidade das imagens também não é boa, pois foi obtido valor médio de presença dos critérios de apenas 55 por cento. CONCLUSÃO: Há necessidade de melhoria/padronização de procedimentos em radiologia convencional, o que pode ser atingido se for implantado um programa de controle e garantia de qualidade no setor de radiologia, incluindo o treinamento dos técnicos, a aferição do desempenho dos equipamentos emissores de radiação e o controle sensitométrico do sistema de processamento radiográfico.


OBJECTIVE: Entrance skin dose, effective dose, and imaging quality in chest radiographs of adult patients have been evaluated. MATERIALS AND METHODS: The study has been developed in eight institutions - seven public hospitals (two of them philanthropic institutions) and one private - in the cities of Agra dos Reis, Cabo Frio, Campos dos Goytacazes, Itaperuna, Niterói, Recife and Rio de Janeiro. Entrance skin dose and effective dose have been evaluated in 735 chest radiographs obtained in posteroanterior/anteroposterior and lateral projections. As regards imaging criteria, 44 radiographs have been evaluated. RESULTS: Variations of up to nine times in entrance skin dose, and six times in effective dose have been detected for a same type of projection. Also, significant discrepancies have been found in values resulting from radiographic techniques employed. Besides, imaging quality has not been good since the rate of compliance with imaging criteria was only 55 percent. CONCLUSION: There is a pressing need for improvement/standardization of procedures in conventional radiology; this can be achieved by implementing a quality control and assurance program in the department of radiology, including training of technicians, x-ray equipment calibration, and sensitometric control of films processors.


Subject(s)
Humans , Dosimetry , Image Interpretation, Computer-Assisted , Radiography, Thoracic , Quality Control , Radiography, Thoracic/radiation effects , Radiography, Thoracic/trends , Sensitivity and Specificity
3.
Radiol. bras ; 38(5): 343-346, set.-out. 2005.
Article in Portuguese | LILACS | ID: lil-417041

ABSTRACT

OBJETIVO: O objetivo deste trabalho é fazer um estudo comparativo das técnicas radiográficas entre o Brasil e a Austrália e avaliar as doses de radiação para os exames radiológicos mais comuns. MATERIAIS E MÉTODOS: A dose de entrada na pele (DEP) e a dose efetiva (DE) foram obtidas com o uso do programa DoseCal. Em ambos os países, o estudo foi realizado em hospitais de grande porte da rede pública. Quatro tipos de exames foram avaliados: tórax, abdome, pelve e coluna torácica em três projeções (ântero-posterior, póstero-anterior e lateral). Na Austrália, todos os equipamentos são digitais e operam no sistema PACS. No Brasil, os aparelhos são convencionais. RESULTADOS: Os valores médios da DEP e da DE são consideravelmente mais altos no Brasil, exceto para os exames de tórax, cujos resultados indicaram índices menores. As maiores diferenças encontradas foram para os exames de pelve (26 vezes maior no Brasil) e de coluna torácica (43 vezes maior no Brasil). O mesmo acontece para os valores da DE. CONCLUSÃO: Nos hospitais australianos, os programas de controle e garantia de qualidade (PCGQ) fazem parte da rotina nos serviços de radiologia. Contam com equipamentos digitais de última geração e os serviços possuem uma equipe de física médica atuante. Esse conjunto de iniciativas resulta na produção de imagens radiográficas de alta qualidade, com baixas doses e índices de rejeição próximos a zero. Tais resultados apontam para a necessidade de se estimular a implantação de PCGQ em toda a rede hospitalar brasileira. No entanto, analisando os resultados de DEP nos exames de tórax, concluímos que doses baixas também são possíveis no Brasil se forem empregadas técnicas radiográficas adequadas.


OBJECTIVE: To compare radiological techniques used in Brazil and in Australia, and to evaluate radiation doses of the most common x-ray procedures. MATERIALS AND METHODS: The entrance skin dose (ESD) and the effective dose (ED) were obtained with the software DoseCal. In both countries the study was conducted in large public hospitals. Four distinct procedures were evaluated: chest, abdomen, pelvis and thoracic spine in three views (anterior-posterior, posterior-anterior and lateral) In Australia, all x-ray equipment are digital and linked with PACS whereas in Brazil conventional equipment is used. RESULTS: The mean values of ESD and ED were consistently higher in Brazil, except for chest x-rays. The higher differences were seen in pelvis (26 fold higher in Brazil) and thoracic spine (43 fold higher in Brazil) radiographs. CONCLUSION: All Australian hospitals have quality assurance programs (QAP) implemented on a permanent basis, the most advanced digital equipment and count with an effective medical physics service. These factors are determinant for high quality images, low rejection rates and low doses imparted to patients when compared to Brazilian standards. Theses results reinforce the need of implementation of quality assurance programs in Brazil. However, when analyzing the results of ESD for chest x-rays, we concluded that low doses can also be achieved in Brazil with the use of appropriate x-ray techniques.


Subject(s)
Humans , Diagnostic Imaging , Dosimetry , Radiometry , Laboratory and Fieldwork Analytical Methods , Australia , Brazil , Radiation Dosage , Dose-Response Relationship, Radiation , Technology, Radiologic
4.
Radiol. bras ; 38(5): 355-358, set.-out. 2005.
Article in Portuguese | LILACS | ID: lil-417043

ABSTRACT

OBJETIVO: Com o intuito de prevenir e minimizar os riscos de ocorrência de danos ambientais, foram avaliados a manipulação e o destino final dos rejeitos e foi elaborado um modelo de gestão para serviços de radiodiagnóstico que visa à obtenção de recursos para o setor. MATERIAIS E MÉTODOS: Foram analisados a manipulação e os rejeitos, baseados em análises de amostras de efluentes das processadoras automáticas de filmes de serviços de radiologia. Foi feita uma análise econômica da viabilidade do modelo proposto. RESULTADOS: As observações in loco enfatizam que os princípios da gestão devem ser obedecidos, ou seja, os componentes dos efluentes (revelador, fixador e água de lavagem) necessitam ser tratados convenientemente antes de serem lançados direta ou indiretamente no meio ambiente, o que não ocorre. A análise econômica confirmou que a receita resultante da comercialização da prata (que varia de 3,5 a 10,2 g/l), recuperada a partir do fixador usado, acrescida da economia proporcionada pela reciclagem do fixador após seu beneficiamento, na pior das hipóteses (quando existe concentração de prata no fixador igual a 3,5 g/l) é suficiente para que toda a despesa correspondente à sua implantação seja paga. CONCLUSÃO: O modelo de gestão proposto demonstra que o reprocessamento do fixador pode ser uma escolha adequada para solucionar os problemas ambientais e financeiros desses serviços. O modelo proposto poderá se tornar, além de ecologicamente correto, uma fonte de recursos para os setores de diagnóstico por imagem e pode ser aplicado a outras instituições, em face da semelhança de problemas e recursos.


OBJECTIVE: With the aim of reducing and preventing environmental damages, handling and disposing practices of chemical effluents from radiology departments were investigated and a service management model was created in order to obtain financial resources for the department. MATERIALS AND METHODS: The proposed model, based on the evaluation of chemical effluents from automatic processors of radiographic films, showed that fixer reprocessing can be an adequate choice to solve environmental and financial problems in these departments. This model also emphasizes that compliance with management guidelines should be observed, i.e. other effluents (developer and water) must be chemically treated before disposal in the natural environment. The economical analysis has confirmed that the income originated from commercializing the silver (of which concentration ranges from 3.5 to 10.2 g/l), recovered from the used fixer, in addition to the income from the reuse of the fixer (after its recovery), is in the worst scenario (when the silver concentration is 3.5 g/l) enough to cover all the expenses with the implementation of the project. CONCLUSION: The proposed model can be a good choice for solution of environmental and financial problems. Moreover, it is ecologically correct, a potential source of financial resources to radiology departments, and can be applied to other institutions due to the similarity of problems and resources.


Subject(s)
Diagnostic Imaging , Fixatives , Environment/economics , Radioactive Effluents , Radioisotopes , Radiology , Waste Management
5.
Radiol. bras ; 38(4): 279-281, jul.-ago. 2005.
Article in Portuguese | LILACS | ID: lil-415886

ABSTRACT

OBJETIVO: Avaliar as condições de biossegurança e de trabalho de profissionais de serviços de radiologia e tecer recomendações sobre as modificações necessárias, a fim de adequar os serviços às normas vigentes no país. MATERIAIS E MÉTODOS: Foram feitas entrevistas com funcionários e observadas as seguintes atividades, executadas pelos técnicos em radiologia ou enfermeiras no local de trabalho: processo de revelação de radiografias dentro das câmaras escuras; tempo médio de permanência dos funcionários nas câmaras escuras; preparação de soluções de fixador e revelador para o processamento radiográfico e tipo de ajuda prestada aos pacientes durante os exames de raios X. Foi avaliada a eficiência do sistema de ventilação de duas câmaras escuras. Foram medidas as alturas das bancadas das câmaras escuras para verificar suas posições e adequação ergonômica. Quanto aos aspectos de segurança elétrica e contra incêndio, foram avaliados o número e a localização de extintores para verificar se estavam de acordo com as normas legais, e a condição de aterramento dos equipamentos elétricos. RESULTADOS: O sistema de ventilação era insuficiente, os profissionais não utilizavam equipamentos de proteção individual no preparo dos produtos químicos, os aspectos ergonômicos estavam em desacordo com as recomendações nacionais e os funcionários apresentam estresse relacionado ao trabalho. CONCLUSÃO: Com base nessas verificações, foram elaborados mapas de risco, para cada setor do serviço de radiologia, que servem para tomadas de decisão quanto a melhorias no ambiente.


Subject(s)
Humans , Protective Devices , Radiation Protection , Radiology , Occupational Health , Radiology Department, Hospital , Risk Map , Stress, Physiological
6.
Radiol. bras ; 37(4): 271-278, jul.-ago. 2004. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-364712

ABSTRACT

Foram realizados testes de controle de qualidade, descritos na Portaria 453/98 do Ministério da Saúde, em sete hospitais públicos do Rio de Janeiro, em um total de 29 tubos de raios X, 30 chassis e 20 vestimentas de proteção individual. Os testes avaliaram o desempenho do gerador de raios X e a geometria do feixe. Foram verificados, também, chassis, "écrans" e negatoscópios, assim como as câmaras claras e escuras. Alguns dos resultados encontrados foram: 55 por cento dos tubos foram reprovados em exatidão e 15 por cento em reprodutibilidade de kVp; 53 por cento foram reprovados em exatidão e 31 por cento em reprodutibilidade de tempo de exposição; 30 por cento foram reprovados em camada semi-redutora; 18 por cento foram reprovados no alinhamento do feixe central; 30 por cento foram reprovados em coincidência de campos; 40 por cento foram reprovados na linearidade de exposição; 64 por cento foram rejeitados no teste de ponto focal. Foram verificadas a guarda inadequada e a falta de recomendação para uso dos aventais plumbíferos. Os resultados dos testes sugerem a necessidade da implementação sistemática de controle de qualidade por um profissional qualificado. A relação de custo-benefício reforça a implantação e a manutenção dos procedimentos contidos e executados neste trabalho, pois tais procedimentos garantiriam a diminuição do custo final do serviço e da dose nos pacientes.


Quality control tests, according to "Portaria 453/98" of the Brazilian Health Ministry, were applied in seven public hospitals of Rio de Janeiro including 29 X-ray tubes, 30 cassettes and 20 individual protection garments. These tests evaluate mainly the X-ray generator and system geometry. Other tests in the accessories were also performed, such as: cassettes, screens, viewing boxes, darkrooms and clear rooms. In the kVp tests, 55% of the equipments were disapproved in exactitude and 15% in reproducibility. Time exactitude and reproducibility were not approved in 53% and 31% of the equipments, respectively. The percentages of disapprovement were: for the HVL (half-value layer) 30%, for beam alignment 18%, for field coincidence 30%, for exposure linearity 40% and for focal spot 64%. It has also been observed that frequently the lead aprons were not kept in appropriate hangers and this procedure may cause damage to these accessories. The results of the test suggest the need of implementation of quality assurance tests in these services. The cost benefit analysis of the results reinforces the importance of the implementation of the recommendations contained in this paper.


Subject(s)
Humans , Radiology Department, Hospital , Radiology Information Systems , Radiology Department, Hospital , Quality Control , Radiography/instrumentation , Radiology Department, Hospital/history , Radiology Information Systems/classification
7.
Radiol. bras ; 37(4): 279-282, jul.-ago. 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-364713

ABSTRACT

Neste trabalho avaliou-se o produto dose área e estimou-se a dose na entrada da pele em exames pediátricos, cujos resultados mostraram valores, em média, 100 por cento acima do adotado como referência para a realização deste trabalho (0,070 mGy). Simultaneamente, fez-se a aferição dos parâmetros técnicos dos equipamentos usados para a obtenção das imagens radiográficas. Os resultados revelaram que o desempenho dos equipamentos está de acordo com a legislação sanitária vigente. Logo, as doses elevadas foram atribuídas ao emprego de técnicas de baixa tensão e à falta de especialização para a realização de exames pediátricos. Realizaram-se medidas das doses absorvidas na região gonadal durante as exposições radiográficas utilizando-se dosímetros termoluminescentes, que se mostraram inadequados para a obtenção destas medidas. Usou-se então uma câmara de ionização e os valores obtidos revelaram que as doses absorvidas sobre a região gonadal estão abaixo dos limites que poderiam causar esterilidade temporária ou permanente.


The dose area product was evaluated and the entrance skin dose was subsequently estimated by means of suitable calculations for pediatric examinations. Results showed values around 100% above the reference levels (0.070 mGy). The technical parameters of the X-ray tubes were periodically checked since a routine quality assurance program is implemented in the hospital. Results showed a good performance of the equipment complying with recommended limits according to Brazilian legislation. Therefore, the high doses can be attributed to the low kV techniques and the lack of appropriate training of the radiographers to perform pediatric examinations. Measurements of scattered radiation were performed in the gonads with the use of thermoluminescent dosimeters which proved to be inadequate for these measurements. Therefore an ionization chamber was used instead and the values obtained showed that the doses were far below the values that can cause permanent or transient sterility.


Subject(s)
Humans , Child, Preschool , Child , Diagnostic Imaging , Radiation Exposure Measurement , Radiography, Thoracic/radiation effects , Radiography, Thoracic/methods , Radiation Dosage , Risk Assessment
8.
Radiol. bras ; 37(3): 185-186, maio-jun. 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-362415

ABSTRACT

A avaliação do processamento radiográfico utilizando o "STEP test" ("sensitometric test for the evaluation of processing") tem como objetivo a identificação de desvios importantes no sistema processadora-químicos-filmes. Neste tipo de avaliação são estabelecidas as condições ideais para o processamento. Um filme padrão é revelado de acordo com as condições do fabricante, ou seja, com padrão igual a 100. O filme é exposto à luz de um sensitômetro calibrado e os valores dos degraus são avaliados com o uso de um densitômetro, sendo obtida sua curva característica (densidade óptica Î degrau). O desvio porcentual máximo deve ser de 20 por cento quando comparado com a curva padrão. Este método é útil na identificação de problemas no processamento radiográfico. Várias processadoras de hospitais públicos/universitários foram avaliadas empregando este método, e verificou-se que aproximadamente 33 por cento das instalações apresentam condições inadequadas de processamento.


Subject(s)
Diagnostic Services , Equipment and Supplies , Outflow Velocity Measurement , X-Ray Film , Technology, Radiologic
9.
Radiol. bras ; 37(1): 29-33, jan.-fev. 2004. ilus
Article in Portuguese | LILACS | ID: lil-358024

ABSTRACT

Foi elaborado um sistema para gerenciamento informatizado dos testes de controle de qualidade exigidos pela Portaria 453/98 da Secretaria de Vigilância Sanitária do Ministério da Saúde, visando otimizar sua execução, armazenamento e interpretação. Os testes de controle de qualidade são parte do programa de garantia de qualidade que deve ser implantado em toda instalação de radiodiagnóstico médico e odontológico. Para isso, foi elaborado um banco de dados utilizando o programa Microsoft Access®, permitindo comunicação direta com o sistema informatizado de gerenciamento das manutenções dos equipamentos de raios X, em implantação no Hospital Universitário Clementino Fraga Filho da Universidade Federal do Rio de Janeiro.

10.
Radiol. bras ; 36(6): 353-361, nov.-dez. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-355955

ABSTRACT

Foi elaborado um modelo de gerenciamento da manutenção dos equipamentos convencionais de raios X no Hospital Universitário Clementino Fraga Filho. O modelo foi implementado em várias etapas, que incluíram visitas a centros hospitalares que gerenciam seus equipamentos, linha de colaboração com a Fundação Oswaldo Cruz para realização de cursos e treinamento de técnicos de eletrônica do hospital, montagem de uma esquemateca dos equipamentos em uso, criação de um programa de gerenciamento utilizando um banco de dados na plataforma Microsoft Windows 98-Access, levantamento operacional e condições de funcionamento dos equipamentos. A criação de uma nova rotina nas manutenções vai ao encontro das necessidades de reduzir o tempo de atendimento, custos, e de melhoria na qualidade da imagem em um serviço de radiodiagnóstico, atendendo também às exigências da Portaria 453/98 do Ministério da Saúde.


We developed a management model for maintenance of hospital radiological X-ray equipment. The model was implemented in several steps including visits to other hospitals where equipment management is also done, collaboration work with "Fundação Oswaldo Cruz" for the realization of courses and a training program for the hospital electronic technicians, organization of a small library with the schemes of the radiological equipment in use at "Hospital Universitário Clementino Fraga Filho", Rio de Janeiro, Brazil, development of a management software using a database from Access (Microsoft Windows) and evaluation of the performance of the radiological equipment. The implementation of a new routine for equipment maintenance fulfils the need for reducing repair delay and costs, improving image quality in radiodiagnosis services, and complying with resolution 453/98 of the Brazilian Ministry of Health.


Subject(s)
Equipment Maintenance/methods , Radiography/instrumentation , Database Management Systems/instrumentation , Staff Development , Medical Informatics Applications
11.
Radiol. bras ; 36(3): 163-167, maio-jun. 2003. tab, graf
Article in Portuguese | LILACS | ID: lil-351025

ABSTRACT

Neste trabalho foi realizado estudo comparativo em radiografias de tórax empregando técnicas de alta e baixa quilovoltagens, tendo como objetivo uma melhoria da qualidade técnica das radiografias, associada a uma redução nas doses fornecidas aos pacientes. O estudo foi realizado em 48 pacientes randomizados, com realização de 70 radiografias de tórax em incidência póstero-anterior, utilizando técnicas de alta quilovoltagem (120 kVp) e carga transmitida de 2,3 mAs, e técnicas de baixa quilovoltagem (70 kVp) e carga transmitida de 5 a 10 mAs. Os valores de doses de entrada na pele foram medidos com um Diamentor. A técnica de baixa quilovoltagem apresentou um aumento de 326 por cento na dose fornecida ao paciente, quando comparada com a técnica de alta quilovoltagem. Com o uso das técnicas de alta quilovoltagem foi constatada, ainda, uma diminuição do número de radiografias de má qualidade que necessitavam repetição, poupando os equipamentos e reduzindo custos por conta da melhoria da qualidade da imagem radiográfica


We compared chest radiographs using high and low kilovoltage techniques with the aim of obtaining best quality techniques as well as a reduction in patient doses. The study was performed in 48 patients randomized that were submitted to 70 postero-anterior chest radiographs using high (120 kVp, 2.3 mAs) and low (70 kVp, 5–10 mAs) kilovoltage techniques. The entrance skin dose values were measured with a Diamentor. The low kilovoltage technique showed a 326% increase of the dose when compared with the high kilovoltage technique. The use of the high kilovoltage technique decreased the number of low quality radiographs that required repetition, thus sparing the equipment and reducing the costs due to best quality radiographic images.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged, 80 and over , Diagnostic Imaging , Radiography, Thoracic , Radiography, Thoracic/methods , Sensitivity and Specificity , Diagnostic Techniques and Procedures , Quality Control
12.
Radiol. bras ; 36(1): 17-20, jan.-fev. 2003. tab
Article in Portuguese | LILACS | ID: lil-331819

ABSTRACT

Analisamos o produto dose-área ("dose area product" - DAP) de 12 pacientes submetidos a videofluoroscopia da deglutição. O objetivo foi estimar a exposição à radiação produzida neste tipo de estudo. Utilizamos medidor de DAP (PTW-Diamentor), que registra, de modo cumulativo, as doses de radiação que atingem o examinado durante todo o procedimento. Obtivemos nossos dados em duas salas dotadas com equipamentos da mesma marca e modelo. O protocolo, rigorosamente o mesmo, foi efetuado por um único e experiente profissional. Os valores do DAP para o estudo da deglutição em três fases (oral, faríngea e esofágica) foram: sala 1 (sete pacientes) - 4.101 cGy.cm² de DAP médio com 577 cGy.cm²/min.; sala 2 (cinco pacientes) - 804 cGy.cm² de DAP médio com 119 cGy.cm²/min. Estes resultados díspares foram obtidos de indivíduos com média de 1,57 m de altura e 56 kg de peso, em protocolo que se cumpriu em cerca de sete minutos. Concluímos que as doses, cinco vezes mais baixas, obtidas na sala 2, retratam mais adequadamente a exposição determinada pela videofluoroscopia da deglutição. Acreditamos que as doses mais altas, da sala 1, embora dentro dos padrões internacionais para exames do tubo digestivo, devam-se ao desconhecimento do desempenho, nem sempre perfeito, dos equipamentos radiológicos. Esta conclusão encontra apoio no fato de, em nosso meio, não ser usual que os serviços de radiodiagnóstico tenham implementado um rotineiro "programa de garantia de qualidade" e aponta para a importância do DAP na qualificação dos métodos e equipamentos radiológicos


We analyzed the dose area product (DAP) of 12 patients submitted to videofluoroscopic swallowing studies. The aim of this study was to establish, in a preliminary manner, the values of radiation exposure for patients submitted to this type of examination. A Diamentor equipment was used to register the cumulative radiation doses emitted by the x-ray tubes. Two different rooms with identical radiological equipment were used to collect the data. The protocol used was rigorously the same and the same experienced professional performed the examinations. DAP's values for the three phases (oral, pharyngeal and esophagogastric) of the videofluoroscopic swallowing study were, for the room A (7 patients), 4,101 cGy.cm², DAP/min. = 577 cGy.cm²/min., and for the room B (5 patients), 804 cGy.cm², DAP/min = 119 cGy.cm²/min. These different results were obtained from patients of the same height and weight, using the same examination time (around 7 minutes) for all patients. We concluded that the data showing doses five times lower in room B are more reliable that those obtained for room A and that DAP and DAP/min. are good elements to inform patient doses imparted by videofluoroscopic swallowing examination. We believe that the high dose differences observed between the two groups are due to lack of calibration of the x-ray equipment, since unfortunately "quality assurance programs" are not routinely implemented.


Subject(s)
Humans , Deglutition/radiation effects , Deglutition/physiology , Radiation Exposure , Radiation Dosage , Fluoroscopy , Quality Assurance, Health Care , Radiometry
13.
Radiol. bras ; 36(1): 27-34, jan.-fev. 2003. tab, graf
Article in Portuguese | LILACS | ID: lil-331821

ABSTRACT

Foi elaborado um Programa de Monitoração Ocupacional em radiologia médica para o Hospital Universitário Clementino Fraga Filho da Universidade Federal do Rio de Janeiro, seguindo as normas e legislação nacional. Para a construção do Programa, realizou-se um levantamento de todos os Serviços e funcionários diretamente expostos às radiações ionizantes. Constatou-se que a maioria desses funcionários não era monitorada, que apenas três Serviços mantinham um controle de dose de trabalhadores com contratos de prestação de serviço independentes e que não havia controle para os casos de doses elevadas. Com a implantação do Programa, os passos seguintes foram a contratação da uma nova empresa que prestasse o serviço de monitoração pessoal, reduzindo significativamente o custo anual de operação com o contrato único para o hospital; a inclusão de mais sete Serviços que trabalham com radiações ionizantes, aumentando em mais de 60 por cento o número de trabalhadores monitorados; o controle de doses elevadas, principalmente no setor de Hemodinâmica, que apresentou a maior média de dose (0,32 mSv/mês); e a monitoração de área, que foi realizada em períodos intercalados nos pontos considerados de maior risco para a população e os trabalhadores. Paralelamente, o Programa de Monitoração Ocupacional foi informatizado, sendo construído um banco de dados com o propósito de controlar e armazenar as doses funcionais. Com a implantação do Programa, começa-se a compreender os riscos de se trabalhar com radiações ionizantes, a partir dos conceitos de proteção radiológica, e conscientiza-se quanto ao uso correto dos monitores de dose


An occupational monitoring program in diagnostic radiology was implemented at the "Hospital Universitário Clementino Fraga Filho – UFRJ", Rio de Janeiro, Brazil, in accordance with the Brazilian legislation. Previously, a survey of all personnel involved with ionizing radiation was performed. Many problems were observed: the great majority of the workers were not properly monitored; only three departments of the hospital kept an independent survey of the occupational doses; there was not a follow-up control of the high doses. With the implementation of the program, a new laboratory was chosen to read the dosemeters and this initiative resulted in reduction of the hospital costs. The inclusion of seven more departments in the program represented an increase of 60% in the number of monitored workers. The program also provided a system to control the high doses, especially in the Hemodynamics department, which presented the highest mean dose value (0.32 mSv/month). An area survey program was performed during different periods in places considered of high risk for the workers and for the public as well. At the same time, a software was used to build a database with the aim of controlling all personnel data. The implementation of the program provided all personnel involved a better knowledge of the risks associated with ionizing radiation and of radioprotection, and also awareness of the need of correct use of the personal dose monitors.


Subject(s)
Humans , Occupational Exposure/classification , Program Evaluation , Radiation Protection/standards , Radiology Department, Hospital/classification , Radiology Department, Hospital , Radiation Dosage , Quality Control , Radiometry
14.
Radiol. bras ; 35(6): 357-363, nov.-dez. 2002. tab, graf
Article in Portuguese | LILACS | ID: lil-331011

ABSTRACT

O controle de qualidade de processadoras automáticas é um dos aspectos mais importantes na implementação de programas de garantia de qualidade em radiodiagnóstico. Um programa piloto de garantia de qualidade para processadoras automáticas utilizando o método sensitométrico foi implementado no serviço de mamografia de um hospital universitário no Rio de Janeiro. Inicialmente foi feita uma avaliação das condições de funcionamento de todas as câmaras escuras do hospital. Foi constatado que apresentavam altos níveis de temperatura e umidade relativa ambiental e várias entradas de luz; nível de fog elevado, que tornava necessário um aumento de até 24% na mAs para compensar a perda de contraste; tempo de processamento seco-a-seco com erros de até 56%; temperatura do revelador de 39°C (4°C a mais do que o recomendado pelo fabricante); taxa de reposição dos produtos químicos com erros de até 417% acima do recomendado pelo fabricante; e índices de rejeição de filmes da ordem de 21%. Medidas sensitométricas feitas antes da implementação do projeto acusaram valores de base + fog de 0,24 densidade óptica, assim como velocidade e contraste fora dos limites recomendados. Os filmes apresentavam vários artefatos produzindo imagens de baixa qualidade. O projeto piloto consistiu na implementação do programa de garantia de qualidade no setor de mamografia do hospital. Muitas outras iniciativas contribuíram para o sucesso do projeto, tais como: treinamento dos técnicos de mamografia, melhor manutenção do mamógrafo e, especialmente, o aumento do número médio de pacientes por dia, de 7 para 12, o que contribuiu para a estabilidade da processadora. Esta iniciativa permitiu que a taxa de reposição dos produtos químicos fosse reduzida a níveis aceitáveis...


Quality control of automatic processors is an important issue in the implementation of quality assurance programs in diagnostic radiology. A pilot program of quality control for automatic processors using the sensitometric method was implemented in the Radiodiagnosis Service of a University Hospital in Rio de Janeiro, RJ, Brazil. An initial survey of the darkrooms showed that they had high temperature and humidity and several light leaks; fog levels were excessively high requiring an increase in mAs of up to 24% to compensate for contrast loss; dry to dry processing time was out of control with errors of up to 56%; developer temperature was as high as 39°C (4°C higher than the recommended by the manufacturers); replenishment rates presented values as high as 417% above manufacturer's recommendations; and rejection rates of radiographic films were of the order of 21% in the mammography service. Sensitometric measurements performed before the implementation of the quality control showed values of base + fog as high as 0.24 optical density and speed and contrast outside recommended limits. The radiographic films presented several artifacts that resulted in low quality images. The pilot program consisted of the implementation of the quality control in the mammography service. Several initiatives were taken including training of the technicians, improvement of maintenance of the processors and increase in the number of patients/day from 7 to 12. This procedure allowed replenishment rates to be lowered to acceptable levels...


Subject(s)
Artifacts , Diagnostic Imaging/instrumentation , X-Ray Film/standards , Gamma Cameras , Sensitivity and Specificity , Technology, Radiologic , Materials Testing/methods , Equipment and Supplies Technology , Quality Control , Radiation, Ionizing , Radiology Department, Hospital
15.
Radiol. bras ; 33(4): 215-25, jul-.ago. 2000. tab, graf
Article in Portuguese | LILACS | ID: lil-277579

ABSTRACT

O trabalho em questäo tem como principal objetivo analisar a formaçäo e capacitaçäo dos alunos de todas as faculdades de odontologia do Estado do Rio de Janeiro e algumas do Estado de Säo Paulo, em relaçäo à radioproteçäo. A metodologia utilizada consistiu em questionários dirigidos aos professores da disciplina de radiologia, aos alunos que já haviam cursado esta disciplina e aos coordenadores ou responsáveis pela disciplina. Os questionários abordavam questöes fechadas e abertas, tendo, portanto, caráter qualitativo e quantitativo. Pela análise crítica das respostas obtidas, pode-se constatar que existe uma deficiência na formaçäo desses alunos, especialmente quando se leva em conta as novas Diretrizes do Ministério da Saúde. Conseqüentemente, sugere-se que as faculdades de odontologia promovam uma reestruturaçäo nos currículos de radiologia para que seus estudantes estejam mais bem preparados para enfrentar o desafio da qualidade profissional.


Subject(s)
Humans , Education, Dental , Radiation Protection/standards
SELECTION OF CITATIONS